Parameter Name |
Intracell F-H HO Stat Time(s) |
---|---|
Description |
This parameter determines the period during which the triggering conditions of the intra-cell full-rate to half-rate handover are met. The intra-cell full-rate to half-rate handover must conform to the P/N criterion. That is, the triggering conditions of the intra-cell full-rate to half-rate handover are met for P consecutive seconds with N measurement seconds. This parameter corresponds to N of the P/N criterion. The triggering conditions of the intra-cell full-rate to half-rate handover are the F2H HO Threshold or the H2F HO Threshold. This parameter is used with the two parameters. |
GUI Value Range |
[1,16] |
Default Value |
5 |
Unit |
Seconds |
Step |
- |
Modification Rules |
None |
Configuration Policy |
The greater the value of this parameter is set, the more difficult the AMR handover can be triggered. |
Recommended Value |
5 |
Parameter Relationship |
None |
BSC Feature |
Handover, AMR |
Parameter Class |
Parameters About Radio Resources |
Caution |
This parameter is available only when HO Control Switch is set to HO Algorithm I. This parameter is invalid when the HO Control Switch is set to HO Algorithm II. |