Parameter Name |
Penalty Time after AMR TCHF-H HO Fail(s) |
---|---|
Description |
This parameter specifies the penalty time for AMR full rate to half rate (FR-to-HR) handovers. Before the timer expires, no AMR FR-to-HR handover is allowed if the previous FR-to-HR handover fails due to channel unavailability or channel mismatch. The greater the value of this parameter is, the longer the penalty time after AMR TCHF-H HO Fail is. In other words, triggering AMR handover becomes more difficult. |
GUI Value Range |
[0,255] |
Default Value |
10 |
Unit |
Seconds |
Step |
- |
Modification Rules |
None |
Configuration Policy |
The greater the value of this parameter is, the longer the penalty time after AMR TCHF-H HO Fail is. In other words, triggering AMR handover becomes more difficult. |
Recommended Value |
10 |
Parameter Relationship |
None |
BSC Feature |
AMR |
Parameter Class |
Parameters About Radio Resources |
Caution |
None |