Allowed Flow Control Level of UL And OL Subcell HO

Parameter Name

Allowed Flow Control Level of UL And OL Subcell HO

Description

If the flow control level in the current system is greater than the value of this parameter, the handover between the UL subcell and the OL subcell due to low or high UL subcell load is not allowed.

GUI Value Range

[0,11]

Default Value

10

Unit

None

Step

-

Modification Rules

None

Configuration Policy

If this parameter is set to a too great or too low value, load balancing between the OL subcell and UL subcell is adversely affected.

Recommended Value

10

Parameter Relationship

None

BSC Feature

Handover

Parameter Class

Parameters About Radio Resources

Caution

None


Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.