Distance Hysteresis Between Boundaries of UL And OL Subcells(dB)

Parameter Name

Distance Hysteresis Between Boundaries of UL And OL Subcells(dB)

Description

To prevent ping-pong handovers, this parameter should be decided before the handover from the OL subcell to the UL subcell. Suppose the signal strength of serving cell is SS(s) and the signal strength of the adjacent cell is SS(n). The decision condition for a handover from the OL subcell to the UL subcell is as follows: SS(s) - SS(n) < Distance between Boundaries of UL And OL Subcells - Distance Hysteresis Between Boundaries of UL And OL Subcells.

GUI Value Range

[0,63]

Default Value

2

Unit

dB

Step

-

Modification Rules

None

Configuration Policy

The greater the value of this parameter is set, the more difficult the handover between the OL subcell and the UL subcell can be triggered.

Recommended Value

2

Parameter Relationship

Distance between Boundaries of UL And OL Subcells(dB)

BSC Feature

Handover

Parameter Class

Parameters About Radio Resources

Caution

None


Huawei Proprietary and Confidential