En Iuo Out Cell Serious OverLoad Threshold

Parameter Name

En Iuo Out Cell Serious OverLoad Threshold

Description

If the channel seizure ratio of the UL subcell is greater than the value of this parameter, the load handover period from the UL subcell to the OL subcell is decreased by the value of Modified step length of UL load HO period per second on the basis of UL subcell load hierarchical HO period, thus speeding up the load handover from the UL subcell to the OL subcell.

GUI Value Range

[0,100]

Default Value

80

Unit

%

Step

-

Modification Rules

None

Configuration Policy

This parameter must be set to a value that is greater than or equal to the En Iuo Out Cell General OverLoad Threshold.

Recommended Value

80

Parameter Relationship

UL subcell load hierarchical HO period(s), Modified step length of UL load HO period(s)

BSC Feature

Handover

Parameter Class

Parameters About Radio Resources

Caution

None


Huawei Proprietary and Confidential