Parameter Name |
Filter Length for TCH NBR_RCVD_BLOCK |
---|---|
Description |
When the Measurement Report Type is EMR, this parameter specifies the filter length for the TCH NBR_RCVD_BLOCK. By setting this parameter, you can use the NBR_RCVD_BLOCK in multiple EMRs, thus avoiding the case that the NBR_RCVD_BLOCK in a single EMR is inaccurate. |
GUI Value Range |
[0,31] |
Default Value |
6 |
Unit |
None |
Step |
- |
Modification Rules |
None |
Configuration Policy |
If this parameter is set to a too great value, the filtered value is more accurate, but the time delay is longer. If this parameter is set to a too small value, the filtered value is inaccurate. Once set, this parameter should not be modified. |
Recommended Value |
6 |
Parameter Relationship |
None |
BSC Feature |
EMR |
Parameter Class |
Parameters About Radio Resources |
Caution |
None |