Filter Length for TCH NBR_RCVD_BLOCK

Parameter Name

Filter Length for TCH NBR_RCVD_BLOCK

Description

When the Measurement Report Type is EMR, this parameter specifies the filter length for the TCH NBR_RCVD_BLOCK.

By setting this parameter, you can use the NBR_RCVD_BLOCK in multiple EMRs, thus avoiding the case that the NBR_RCVD_BLOCK in a single EMR is inaccurate.

GUI Value Range

[0,31]

Default Value

6

Unit

None

Step

-

Modification Rules

None

Configuration Policy

If this parameter is set to a too great value, the filtered value is more accurate, but the time delay is longer. If this parameter is set to a too small value, the filtered value is inaccurate. Once set, this parameter should not be modified.

Recommended Value

6

Parameter Relationship

None

BSC Feature

EMR

Parameter Class

Parameters About Radio Resources

Caution

None


Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.