Parameter Name |
Edge HO AdjCell Watch Time(s) |
---|---|
Description |
According to the P/N criterion, if the adjacent cell keeps meeting the triggering conditions of edge handover for P consecutive times within N times, an edge handover to the adjacent cell is triggered. This parameter corresponds to N of the P/N criterion. |
GUI Value Range |
[1,16] |
Default Value |
3 |
Unit |
Seconds |
Step |
- |
Modification Rules |
None |
Configuration Policy |
The greater the value of this parameter is set, the more difficult the edge handover can be triggered. |
Recommended Value |
3 |
Parameter Relationship |
Edge HO AdjCell Valid Time(s) |
BSC Feature |
Handover |
Parameter Class |
Parameters About Radio Resources |
Caution |
This parameter is available only when HO Control Switch is set to HO Algorithm I. This parameter is invalid when the HO Control Switch is set to HO Algorithm II. |