UmPenaltyTimer

Parameter Name

UmPenaltyTimer

Description

This parameter specifies the value of the timer used for adjacent cell penalty after handover failure due to the Um interface error.

GUI Value Range

[0,255]

Default Value

10

Unit

Seconds

Step

-

Modification Rules

None

Configuration Policy

If this parameter is set to a too great value, the target cell for the previous handover will not be selected for the next handover, but the probability of call drop increases. If this parameter is set to a too small value, the probability of handover failure increases.

Recommended Value

10

Parameter Relationship

None

BSC Feature

Handover

Parameter Class

Parameters About Radio Resources

Caution

None


Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.