Parameter Name |
RXQUAL9 |
---|---|
Description |
If the receive level of the serving cell is in the range of 53 to 55, and if the uplink or downlink receive quality of the non-AMR FR voice service is greater than or equal to the value of this parameter, uplink interference or downlink interference exists. The value of this parameter corresponds to multiplying quality level 0 to 7 by 10. |
GUI Value Range |
[0,70] |
Default Value |
43 |
Unit |
None |
Step |
- |
Modification Rules |
None |
Configuration Policy |
This parameter is used in handover decision. An uplink interference handover is easily triggered if this parameter is set to a too small value. |
Recommended Value |
43 |
Parameter Relationship |
None |
BSC Feature |
Handover |
Parameter Class |
Parameters About Radio Resources |
Caution |
None |