DtxMeasUsed

Parameter Name

DtxMeasUsed

Description

This parameter is used as a switch to control the value determination method of measurement reports. When this parameter is set to Open, if DTX is used, the SUB values in the MR should be selected. Otherwise, the PULL values in the MR should be selected.

GUI Value Range

[Close,Open]

Default Value

Open

Unit

None

Step

-

Modification Rules

None

Configuration Policy

When this parameter is set to 0 and if the measurement report indicates that DTX is not used, the FULLSET values should be selected. When this parameter is set to 0 and if the measurement report indicates that DTX is used, the SUBSET values should be selected. In latter cases, the SUBSET values should be used irrespective of how DTX is indicated in the subsequent measurement reports.

When this parameter is set to 1, whether the FULLSET values or the SUBSET values should be selected depends on the DTX indication bit in the measurement report. That is, if the measurement report indicates that DTX is used, the SUBSET values should be selected; otherwise, the FULLSET values should be selected.

Recommended Value

Open

Parameter Relationship

None

BSC Feature

Handover, power control, discontinuous transmission and discontinuous reception

Parameter Class

Parameters About Radio Resources

Caution

None


Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.