Parameter Name |
Quick Handover Up Trigger Level(dB) |
---|---|
Description |
During a measurement period, if the filtered uplink level of the serving cell is smaller than the value of this parameter, a quick handover is triggered. The level values 0 through 63 map to -110 dBm to -47 dBm. |
GUI Value Range |
[0,63] |
Default Value |
50 |
Unit |
Levels |
Step |
- |
Modification Rules |
None |
Configuration Policy |
None |
Recommended Value |
50 |
Parameter Relationship |
This parameter is used in combination with the following parameters: Quick Handover Static Time(0.5s), Quick Move Speed Threshold(m/s), Quick Handover Last Time (0.5s), and Quick Handover Offset(dB). |
BSC Feature |
Handover |
Parameter Class |
Parameters About Radio Resources |
Caution |
None |