Quick Handover Down Trigger Level(dB)

Parameter Name

Quick Handover Down Trigger Level(dB)

Description

During a measurement period, if the compensated downlink level of the serving cell is smaller than the value of this parameter, a quick handover is triggered.

The level values 0 through 63 map to -110 dBm to -47 dBm.

GUI Value Range

[0,63]

Default Value

50

Unit

Levels

Step

-

Modification Rules

None

Configuration Policy

None

Recommended Value

50

Parameter Relationship

This parameter is used in combination with the following parameters: Quick Handover Static Time(0.5s), Quick Move Speed Threshold(m/s), Quick Handover Last Time (0.5s), and Quick Handover Offset(dB).

BSC Feature

Handover

Parameter Class

Parameters About Radio Resources

Caution

None


Huawei Proprietary and Confidential