Parameter Name |
Quick Handover Last Time (0.5s) |
---|---|
Description |
The quick handover must comply with the P/N criterion. That is, the triggering conditions of quick handover must be met for P consecutive times within N times. This parameter corresponds to P of the P/N criterion, that is, the period during which the triggering conditions of quick handover are met. Such a period is within the value defined by this parameter. |
GUI Value Range |
[1,32] |
Default Value |
3 |
Unit |
Seconds |
Step |
0.5s |
Modification Rules |
None |
Configuration Policy |
The greater the value of this parameter is set, the more difficult the fast-moving handover can be triggered. |
Recommended Value |
3 |
Parameter Relationship |
This parameter is used in combination with the following parameters: Quick Handover Static Time(0.5s), Quick Move Speed Threshold(m/s), and Quick Handover Offset(dB). |
BSC Feature |
Handover |
Parameter Class |
Parameters About Radio Resources |
Caution |
None |