Parameter Name |
Edge HO Watch Time(0.5s) |
---|---|
Description |
According to the P/N criterion, if the UL or DL receive level is lower than its corresponding edge handover threshold for P consecutive times within N times, an edge handover is triggered. This parameter corresponds to P of the P/N criterion, and applies only to HO Algorithm II. |
GUI Value Range |
[1,16] |
Default Value |
1 |
Unit |
0.5 Seconds |
Step |
- |
Modification Rules |
None |
Configuration Policy |
The greater the value of this parameter is set, the more difficult the edge handover can be triggered. |
Recommended Value |
1 |
Parameter Relationship |
Edge HO Valid Time(0.5s) |
BSC Feature |
Handover |
Parameter Class |
Parameters About Radio Resources |
Caution |
This parameter is available only when HO Control Switch is set to HO Algorithm II. This parameter is invalid when the HO Control Switch is set to HO Algorithm I. |