Edge HO AdjCell Watch Time(0.5s)

Parameter Name

Edge HO AdjCell Watch Time(0.5s)

Description

According to the P/N criterion, if the adjacent cell keeps meeting the triggering conditions of edge handover for P consecutive times within N times, an edge handover to the adjacent cell is triggered.

This parameter corresponds to N of the P/N criterion.

GUI Value Range

[1,16]

Default Value

1

Unit

0.5Seconds

Step

-

Modification Rules

None

Configuration Policy

The greater the value of this parameter is set, the more difficult the edge handover can be triggered.

Recommended Value

1

Parameter Relationship

Edge HO AdjCell Valid Time(0.5s)

BSC Feature

Handover

Parameter Class

Parameters About Radio Resources

Caution

This parameter is available only when HO Control Switch is set to HO Algorithm II. This parameter is invalid when the HO Control Switch is set to HO Algorithm I.