Parameter Name |
Filter Length for DL Qual. |
---|---|
Description |
This parameter specifies the number of measurement reports sampled for calculating the average value of the downlink signal quality before the BTS power adjustment. |
GUI Value Range |
[1,20] |
Default Value |
5 |
Unit |
None |
Step |
- |
Modification Rules |
None |
Configuration Policy |
On receiving some consecutive measurement reports, the network calculates the average value of the downlink signal quality. This average value indicates the radio environment of the MS. When you configure this parameter, you must consider the delay and accuracy of the average value caused by the number of measurement reports. |
Recommended Value |
5 |
Parameter Relationship |
None |
BSC Feature |
Power control |
Parameter Class |
Parameters About Radio Resources |
Caution |
If measurement reports are preprocessed at the BTS side, the BTS performs the compensation of the measurement reports. If measurement reports are preprocessed at the BSC side, the BSC performs the compensation of the measurement reports. |