UL RX_LEV Upper Threshold

Parameter Name

UL RX_LEV Upper Threshold

Description

The power control step is calculated based on the signal level. The signal level has an upper threshold and a lower threshold. Power control is not performed if the signal level is between the upper threshold and the lower threshold. Power control is performed only when the signal level exceeds the upper threshold or is below the lower threshold.

The level values 0 through 63 map to -110 dBm to -47 dBm.

GUI Value Range

[0,63]

Default Value

30

Unit

Levels

Step

-

Modification Rules

None

Configuration Policy

If this parameter is set to a too great value, the uplink level becomes high without power control. Thus, the battery life is reduced and the network interference is increased. If this parameter is set to a too small value, the uplink level becomes low, and call drop may easily occur.

The value of this parameter is equal to that of UL Expected Level at HO Access.

Recommended Value

30

Parameter Relationship

This parameter specifies the upper threshold of the uplink signal for power control. If the signal level is higher than this threshold, calculate a decreased value (= receive level - (UL RX_LEV Upper Threshold + UL RX_LEV Lower Threshold)/2 ). Compare the decreased value with MAX Down Adj.Value Qual.Zone 0, MAX Down Adj.Value Qual.Zone 1, MAX Down Adj.Value Qual.Zone 2, and MAX Down Adj. PC Value by Qual. Set the power adjustment step to the minimum value of the five.

BSC Feature

Power control

Parameter Class

Parameters About Radio Resources

Caution

For details, refer to UL RX_LEV Upper Threshold.