MAX Down Adj.Value Qual.Zone 0

Parameter Name

MAX Down Adj.Value Qual.Zone 0

Description

In Huawei II power control algorithm, the quality zone is divided into three grades (0, 1-2, ≥ 3) based on the receive quality (RQ). A maximum step length of power control is set for each quality zone.

When downward power adjustment is performed based on the level, the maximum permissible down adjustment step differs based on the receive quality.

This parameter determines the maximum permissible down adjustment step when RQ is 0.

GUI Value Range

[0,30]

Default Value

2

Unit

dB

Step

-

Modification Rules

None

Configuration Policy

If this parameter is set to a too small value, the algorithm cannot realize fast power control. If this parameter is set to a too great value, the effectiveness of power control cannot be guaranteed.

Recommended Value

2

Parameter Relationship

None

BSC Feature

Power control

Parameter Class

Parameters About Radio Resources

Caution

None


Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.