AMR MAX Down Adj. Value Qual. Zone 1

Parameter Name

AMR MAX Down Adj. Value Qual. Zone 1

Description

This parameter specifies the AMR maximum down adjustment step permitted by the quality zone 1 (the RQ value is greater than 0 and less than 3) based on the signal level.

In the Huawei II power control algorithm, the quality zone is divided into three grades (0, 1-2, ≥ 3) based on the receive quality (RQ). Every quality zone has different maximum permissible down adjustment step.

When the downward power adjustment is performed based on the level, the maximum permissible down adjustment step differs based on the receive quality.

This parameter specifies the maximum step length in decreasing the signal level in power control when the RQ is 1.

GUI Value Range

[0,30]

Default Value

0

Unit

dB

Step

-

Modification Rules

None

Configuration Policy

If this parameter is set to a lower value, the algorithm cannot realize fast power control. If this parameter is set to a higher value, the effectiveness of power control cannot be guaranteed.

Recommended Value

0

Parameter Relationship

None

BSC Feature

Power control, AMR

Parameter Class

Parameters About Radio Resources

Caution

None


Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.