AMR DL Qual Bad Trig Threshold

Parameter Name

AMR DL Qual Bad Trig Threshold

Description

In downlink power control, if the downlink receive quality is greater than or equal to this threshold, then the actual DL RX_LEV Upper Threshold should contain DL Qual. Bad UpLEVDiff. This parameter further improves the expected level of the downlink power control.

Level 0: BER smaller than 0.2%

Level 1: BER ranges from 0.2% to 0.4%

Level 2: BER ranges from 0.4% to 0.8%

Level 3: BER ranges from 0.8% to 1.6%

Level 4: BER ranges from 1.6% to 3.2%

Level 5: BER ranges from 3.2% to 6.4%

Level 6: BER ranges from 6.4% to 12.8%

Level 7: BER greater than 12.8%

GUI Value Range

[0,7]

Default Value

2

Unit

Levels

Step

-

Modification Rules

None

Configuration Policy

None

Recommended Value

2

Parameter Relationship

None

BSC Feature

Power control, AMR

Parameter Class

Parameters About Radio Resources

Caution

None


Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.