HwIII UL Filter Adjust Factor

Parameter Name

HwIII UL Filter Adjust Factor

Description

This parameter specifies the filter adjustment factor for uplink power control. If this parameter is set to a large value, the filtered values become smooth, thus reducing the impact of poor measurement reports on the filtered values. If this parameter is set to a small value, the filter values are close to the actual ones and thus the power control speed is increased. It is recommended that the default value be used.

GUI Value Range

[1,10]

Default Value

3

Unit

None

Step

-

Modification Rules

None

Configuration Policy

None

Recommended Value

3

Parameter Relationship

None

BSC Feature

Power control

Parameter Class

Parameters About Radio Resources

Caution

None


Huawei Proprietary and Confidential