Parameter Name |
Filter Length for TCH Qual. |
---|---|
Description |
This parameter specifies the number of measurement reports that are used to clculate the signal quality on speech/data TCHs. The signal quality on TCHs should not be determined based on only one measurement result. To eliminate the influence of accidental factors, you need to obtain the average value of signal quality in several successive measurement reports of TCHs, and then determine the signal quality on speech/data TCHs. |
GUI Value Range |
[1,32] |
Default Value |
6 |
Unit |
None |
Step |
- |
Modification Rules |
None |
Configuration Policy |
If this parameter is set to a higher value, the influence of accidental factors may be reduced but the judgment of channel status may not be in time. If this parameter is set to a lower value, the judgment is imprecise. |
Recommended Value |
6 |
Parameter Relationship |
None |
BSC Feature |
Channel Management |
Parameter Class |
Parameters About Radio Resources |
Caution |
None |