Update Period of CH Record(min)

Parameter Name

Update Period of CH Record(min)

Description

When the Update Period of CH Record expires, the process of updating the history record of channel occupancy is started. That is, the history priority of each channel is reduced by Update Freq.of CH Record at the interval of the setting value of this parameter to increase the channel priority.

Principles of taking values are as follows:

Generally, a high-frequency adjustment is used. For example, the update period should be set in such a way that it ranges from half an hour to one hour because several busy hours are the major concerns during the actual operation in a day. If the parameter is set to a too small value, the result of the history record is meaningless. If the parameter is set to a too great value, the result cannot be seen in time during busy hours.

If a fixed interference source exists or an equipment fault occurs, the update period for the affected cells can be set in such a way that it ranges from several hours to one day.

This parameter is used together with Update Freq. of CH Record so that the channel can be assigned even if the history record priority decreases.

GUI Value Range

[1,1440]

Default Value

30

Unit

Minutes

Step

-

Modification Rules

None

Configuration Policy

None

Recommended Value

30

Parameter Relationship

None

BSC Feature

Channel Management

Parameter Class

Parameters About Radio Resources

Caution

None


Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.