Factory Mode

Parameter Name

Factory Mode

Description

This parameter specifies whether to enable or disable the factory mode channel assignment algorithm. If this parameter is set to ON, the BSC evenly assigns channels to the TRXs in a cell. Generally, at the initial stage of site deployment, each TRX is evenly assigned channels. You need to check the connection cable between TRX and RF with no need to perform a dialing test on site. After the initial stage or in other scenarios, it is recommended that this parameter be set to OFF.

GUI Value Range

[OFF,ON]

Default Value

OFF

Unit

None

Step

-

Modification Rules

None

Configuration Policy

None

Recommended Value

OFF

Parameter Relationship

None

BSC Feature

None

Parameter Class

Parameters About Radio Resources

Caution

None


Huawei Proprietary and Confidential