T3101(ms)

Parameter Name

T3101(ms)

Description

This parameter specifies the timer used in the immediate assignment procedure.

The T3101 is started when the BSC sends an IMM ASS message to the BTS. If the BSC receives an EST IND message before T3101 expires, T3101 is stopped; if T3101 expires before the BSC receives an EST IND message, the BSS releases the seized SDCCH.

GUI Value Range

[500,60000]

Default Value

3000

Unit

Milliseconds

Step

-

Modification Rules

None

Configuration Policy

If this timer is set to a higher value, this may waste the channel resources and cause the congestion.

If this timer is set to a lower value, this may influence the immediate assignment success rate.

Recommended Value

3000

Parameter Relationship

None

BSC Feature

Channel Management

Parameter Class

Parameters About Radio Resources

Caution

None