Parameter Name |
T3103A(ms) |
---|---|
Description |
In an intra-BSC handover, the timer T3103 is initiated after the BSC sends a handover command. Before the timer T3103 expires, the timer stops if the BSC receives a Handover Complete message. After the timer expires, the BSC sends a handover failure message. |
GUI Value Range |
[500,60000] |
Default Value |
10000 |
Unit |
Milliseconds |
Step |
- |
Modification Rules |
None |
Configuration Policy |
If this timer is set to a higher value, this may waste the channel resources and cause the congestion. If this timer is set to a lower value, this may influence the handover success rate. |
Recommended Value |
10000 |
Parameter Relationship |
None |
BSC Feature |
Channel Management |
Parameter Class |
Parameters About Radio Resources |
Caution |
None |