T7(ms)

Parameter Name

T7(ms)

Description

In an outgoing BSC handover, after the BSC sends a handover request message, the timer T7 is initiated. Before the timer T7 expires, the timer T7 stops if the BSC receives a handover acknowledgment message. After the timer T7 expires, the BSC sends an outgoing BSC handover failure message.

GUI Value Range

[500,60000]

Default Value

10000

Unit

Milliseconds

Step

-

Modification Rules

None

Configuration Policy

If this timer is set to a higher value, this may waste the channel resources and cause the congestion.

If this timer is set to a lower value, this may influence the handover success rate.

Recommended Value

10000

Parameter Relationship

None

BSC Feature

Channel Management

Parameter Class

Parameters About Radio Resources

Caution

None


Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.