T3122(s)

Parameter Name

T3122(s)

Description

This parameter specifies the timer carried by the WaitIndcation information element when the BSC sends an immediate assignment reject message to an MS.

After the MS receives the immediate assignment reject message, the MS makes another attempt to access the network after the timer expires.

GUI Value Range

[0,255]

Default Value

10

Unit

Seconds

Step

-

Modification Rules

None

Configuration Policy

If this timer is set to a lower value, this may increase the channel load and influence the access success rate.

Recommended Value

10

Parameter Relationship

None

BSC Feature

Channel Management

Parameter Class

Parameters About Radio Resources

Caution

None