Parameter Name |
T3103C(ms) |
---|---|
Description |
In an intra-cell handover, the timer T3103C is initiated after the BSC receives the HANDOVER COMMAND from target channel. The timer stops after the BSC receives the HANDOVER COMPLETE message. After the timer expires, the BSC sends a handover failure message. |
GUI Value Range |
[500,60000] |
Default Value |
10000 |
Unit |
Milliseconds |
Step |
- |
Modification Rules |
None |
Configuration Policy |
If this timer is set to a higher value, this may waste the channel resources and cause the congestion. If this timer is set to a lower value, this may influence the handover success rate. |
Recommended Value |
10000 |
Parameter Relationship |
None |
BSC Feature |
Channel Management |
Parameter Class |
Parameters About Radio Resources |
Caution |
None |