Aiding Delay Protect Time(min)

Parameter Name

Aiding Delay Protect Time(min)

Description

This parameter specifies the delay of TRX aiding detection performed after the cell is initialized.

The cell is unstable after initialization; therefore, if the TRX aiding detection starts immediately after cell initialization, a wrong decision might be made. In such a case, this parameter is used to specify a delay.

GUI Value Range

[1,60]

Default Value

15

Unit

Minutes

Step

-

Modification Rules

None

Configuration Policy

If the parameter is set too small, a wrong decision might be made in TRX aiding detection; if the parameter is set too large, a faulty main-BCCH might lead to delayed triggering of TRX aiding function after cell initialization.

Recommended Value

15

Parameter Relationship

None

BSC Feature

TRX Aiding

Parameter Class

Parameters About Radio Resources

Caution

None


Huawei Proprietary and Confidential