Parameter Name |
ICB Allowed |
---|---|
Description |
This parameter specifies whether to enable the ICB function in the BTS. If this parameter is set to Yes, the TCHs on the same module on the non-BCCH TRXs are preferentially assigned. In this way, the TRXs on the same module on the BCCH are idle and thus the ICB function can be enabled in the BTS. |
GUI Value Range |
[No,Yes,None] |
Default Value |
No |
Unit |
None |
Step |
- |
Modification Rules |
None |
Configuration Policy |
None |
Recommended Value |
None |
Parameter Relationship |
None |
BSC Feature |
None |
Parameter Class |
Parameters About Radio Resources |
Caution |
None |