Parameter Name |
PBGT HO Threshold |
---|---|
Description |
This parameter specifies that the PBGT handover to an adjacent cell occurs when the difference between the downlink level of the adjacent cell and that of the serving cell is greater than PBGT HO Threshold.If the value is lower than 64, the handover to the adjacent cell whose level is lower than the serving cell can be performed. The level values 0 to 127 map to -64 dB to 63 dB. |
GUI Value Range |
[0,127] |
Default Value |
68 |
Unit |
dB |
Step |
- |
Modification Rules |
None |
Configuration Policy |
Reducing PBGT HO Threshold makes the PBGT handover more accessible. If the PBGT HO Threshold is set to an excessively smaller value, ping-pong handover may easily occur.It is recommended that you set this parameter to approximately 68 in densely-populated urban areas and 72 in suburban areas. |
Recommended Value |
68 |
Parameter Relationship |
None |
BSC Feature |
Handover |
Parameter Class |
Parameters About Radio Resources |
Caution |
None |