Inter-cell HO Hysteresis

Parameter Name

Inter-cell HO Hysteresis

Description

This parameter specifies the hysteresis of the handover between adjacent cells at the same layer.

GUI Value Range

[0,63]

Default Value

4

Unit

dB

Step

-

Modification Rules

None

Configuration Policy

This parameter is set to avoid ping-pong handovers.If the cells are at different layers, this parameter is invalid. The value of this parameter needs to be adjusted according to the statistics of the performance and the actual network.Flexible adjustment of the value has a positive effect on the handover and traffic between two adjacent cells.

Recommended Value

It is recommended that you set this parameter to approximately 4 in densely-populated urban areas and 8 in suburban areas.

Parameter Relationship

None

BSC Feature

Handover

Parameter Class

Parameters About Radio Resources

Caution

None