Power Finetune

Parameter Name

Power Finetune

Description

This parameter specifies the following: Currently, when the BSC performs the static power control on the TRX, the step of increasing or reducing the power of the TRX is 2 dB. In some scenarios, the TRX has different losses if it is combined on different tributaries, and the output power difference before and after the combination is not an integral multiple of 2 dB. Thus, the cabinet top output power of the BTS cannot be adjusted in the step of 2 dB, so the TRX output power may be different from the cabinet top output power of the BTS.

Therefore, through the setting of this parameter, a finer step can be provided for adjusting the cabinet top output power of the BTS.

GUI Value Range

[0.0 dB,-0.2 dB,-0.4 dB,-0.6 dB,-0.8 dB,-1.0 dB,-1.2 dB,-1.4 dB,-1.6 dB,-1.8 dB,Default]

Default Value

Default

Unit

0.2 dB

Step

-

Modification Rules

None

Configuration Policy

If this parameter is set to a too great or too small value, the cabinet top output power of the BTS is different from the TRX output power, resulting in the failure of channel allocation.

Recommended Value

Default

Parameter Relationship

None

BSC Feature

None

Parameter Class

Parameters About Equipment

Caution

None


Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.