Parameter Name |
Power Overload Threshold In Ho. In(VA) |
---|---|
Description |
If the sum of the maximum output power of the power amplifier and the value of this parameter is greater than the total power of BTS, an incoming handover can be performed. |
GUI Value Range |
[0,50] |
Default Value |
8 |
Unit |
Watt |
Step |
- |
Modification Rules |
None |
Configuration Policy |
None |
Recommended Value |
8 |
Parameter Relationship |
None |
BSC Feature |
None |
Parameter Class |
Parameters About Equipment |
Caution |
The value of the Power Overload Threshold In Ho. In parameter must be smaller than or equal to the value of the Power Overload Threshold In Ho. Out parameter. This is to ensure that other timeslots or cells do not carry heavy power load because of the power insufficiency handover. |