Parameter Name |
Receive MSC Config. Msg. Timer |
---|---|
Description |
This parameter specifies the length of the timer for the MSC in the MSC pool to broadcast its available capacity. |
GUI Value Range |
[1,15] |
Default Value |
5 |
Unit |
Seconds |
Step |
- |
Modification Rules |
None |
Configuration Policy |
If this parameter is set to a too great value, the MSC capacity recorded by the BSC is inaccurate. If this parameter is set to a too small value, the A interface is overloaded. |
Recommended Value |
5 |
Parameter Relationship |
None |
BSC Feature |
Flow Control |
Parameter Class |
Parameters About Equipment |
Caution |
None |