Parameter Name |
CicPool Send Flag In Ho Fail |
---|---|
Description |
This parameter specifies whether the HO FAIL message carries the circuit pool information. |
GUI Value Range |
[No,Yes] |
Default Value |
Yes |
Unit |
None |
Step |
- |
Modification Rules |
None |
Configuration Policy |
This parameter should be set on the basis of the negotiation with the MSC at the peer end so that the MSC can process the HO FAIL message properly. |
Recommended Value |
Yes |
Parameter Relationship |
None |
BSC Feature |
None |
Parameter Class |
Parameters About Equipment |
Caution |
Circuits are classified according to the bearing capability and service type. The configuration of the circuit pool on the BSC side should be the same as that of the circuit pool on the MSC side. There are totally 22 types of circuit pools in Phase 2 or later-version protocol. Where, circuit pools 1 and 3 support only the Full Rate Speech Service of type 1. Circuit pools 4 and 6 support only the Enhanced Full Rate Speech Service of type 2. Circuit pools 5, 7, 10, 13, 20, 21, and 22 support both the Full Rate Speech Service and the Enhanced Full Rate Speech Service. Circuit pools 2, 8, 9, 11, 12, 14, 15, 16, 17, 18, and 19 support neither the Full Rate Speech Service nor the Enhanced Full Rate Speech Service. According to the information about circuit pools, the BSC can check the circuits assigned and services supported by the MSC. If the circuit pool where the MSC-assigned circuits are located does not match the assigned services, the assignment fails. For example, if the circuit assigned by the MSC is in circuit pool 1 and the speech code algorithm is EFR, the assignment fails. |