Description

This parameter specifies whether the Handover Perform message carries speech_ver.

GUI Value Range

[No,Yes]

Default Value

Yes

Unit

None

Step

-

Modification Rules

None

Configuration Policy

This parameter should be set on the basis of the negotiation with the MSC at the peer end so that the MSC can process the Handover Perform message properly.

Recommended Value

Yes

Parameter Relationship

None

BSC Feature

None

Parameter Class

Parameters About Equipment

Caution

For SDCCH handovers, the Handover Perform message does not carry speech_ver even if this parameter is set to Yes.