Parameter Name |
HO_RQDSpeech Ver |
---|---|
Description |
This parameter specifies whether the HO_RQD message from the BSC to the MSC carries Speech Ver. |
GUI Value Range |
[No,Yes] |
Default Value |
No |
Unit |
None |
Step |
- |
Modification Rules |
None |
Configuration Policy |
This parameter should be set on the basis of the negotiation with the MSC at the peer end. |
Recommended Value |
No |
Parameter Relationship |
None |
BSC Feature |
None |
Parameter Class |
Parameters About Equipment |
Caution |
None |