Feed Tributary 0 Alarm Mode

Parameter Name

Feed Tributary 0 Alarm Mode

Description

This parameter specifies the mode used by the DATU to report an alarm about feed tributary 0. The three modes are as follows:

Mode 1: In this mode, there is only one alarm severity. The current for alarming is constant and higher than the normal operating current.

Mode 2: In this mode, there are two alarm severities: warning alarm and critical alarm. The current for alarming is constant and higher than the normal operating current.

Mode 3: In this mode, there are two alarm severalties: warning alarm and critical alarm. The current for reporting a warning alarm is a periodic pulse. The current for reporting a critical alarm is a constant current.

GUI Value Range

[Mode1,Mode2,Mode3]

Default Value

Mode1

Unit

None

Step

-

Modification Rules

None

Configuration Policy

None

Recommended Value

Mode1

Parameter Relationship

None

BSC Feature

None

Parameter Class

Parameters About Equipment