Low-Temperature Startup Load Power-off Allowed State

Parameter Name

Low-Temperature Startup Load Power-off Allowed State

Description

This parameter specifies whether to power off the TRX when the temperature in the BTS cabinet is too low.

If this parameter is set to Yes, then the BTS powers off the TRX to protect it and reports a Load Power Off Alarm when the temperature in the BTS cabinet is too low. When the temperature rises to 0℃, the BTS powers on the TRX again and the alarm is cleared.

GUI Value Range

[No,Yes]

Default Value

No

Unit

None

Step

-

Modification Rules

None

Configuration Policy

None

Recommended Value

No

Parameter Relationship

None

BSC Feature

None

Parameter Class

Parameters About Equipment

Caution

None


Huawei Proprietary and Confidential