Parameter Name |
Special Analog Alarm Disable Configuration |
---|---|
Description |
The value of this parameter is composed of five bits, that is, alarm switches 5 to 1 from left to right. Each bit specifies whether to disable an analog alarm. The value 0 indicates that the alarm is enabled, and the value 1 indicates that the alarm is disabled. If a switch is selected, the corresponding alarm is disabled. The BTS3012AE supports the following five analog alarms: Battery Temperature 2 (Disabled), Environment Temperature 2 (Disabled), Environment Temperature 1 (Disabled), Environment Humidity (Disabled), and Battery Temperature 1 (Disabled) |
GUI Value Range |
[Battery Temperature 2(Disabled), Environment Temperature 2(Disabled), Environment Temperature 1(Disabled), Environment Humidity(Disabled), Battery Temperature 1(Disabled)] |
Default Value |
11000 |
Unit |
None |
Step |
- |
Modification Rules |
None |
Configuration Policy |
None |
Recommended Value |
11000 |
Parameter Relationship |
None |
BSC Feature |
None |
Parameter Class |
Parameters About Equipment |
Caution |
None |