Parameter Name |
Special Analog Alarm Disable Configuration |
---|---|
Description |
The value of this parameter is composed of three bits, that is, alarm switches 3 to 1 from left to right. Each bit specifies whether to disable an analog alarm. The value 0 indicates that the alarm is enabled, and 1 indicates that the alarm is disabled. For the BTS3006C, the APMU supports the following three special analog alarms: Environment Temperature 1 (Disabled), Preserved Parameter (Disabled), and Battery Temperature 1 (Disabled)] |
GUI Value Range |
[Environment Temperature 1(Disabled), Preserved Parameter(Disabled), Battery Temperature 1(Disabled)] |
Default Value |
010 |
Unit |
None |
Step |
- |
Modification Rules |
None |
Configuration Policy |
None |
Recommended Value |
010 |
Parameter Relationship |
None |
BSC Feature |
None |
Parameter Class |
Parameters About Equipment |
Caution |
None |