Parameter Name |
Alarm Disable Configuration |
---|---|
Description |
This parameter specifies whether to enable or disable one route of alarm. The parameter is expressed in four bits, each of which indicates the enabling or disabling of one route of alarm. Bit 0 indicates that the alarm is enabled whereas bit 1 indicates that the alarm is disabled. The DTCU supports four routes of alarms: route 1 Boolean alarm (disabled), route 2 Boolean alarm (disabled), route 3 Boolean alarm (disabled), and route 4 Boolean alarm (disabled). Route 1 Boolean alarm is the door status alarm. Route 2 Boolean alarm is the AC lightning arrester alarm. Route 3 Boolean alarm is the DC lightning arrester alarm. Route 4 Boolean alarm is reserved. |
GUI Value Range |
[Alarm Switch 4 (Disabled), Alarm Switch 3 (Disabled), Alarm Switch 2 (Disabled), Alarm Switch 1 (Disabled)] |
Default Value |
1111 |
Unit |
None |
Step |
- |
Modification Rules |
None |
Configuration Policy |
None |
Recommended Value |
None |
Parameter Relationship |
None |
BSC Feature |
None |
Parameter Class |
Parameters About Equipment |
Caution |
The parameters "Alarm Disable Configuration"are valid for the DTCU only. |