Common Alarm Switch Valid Level Configuration(25~32)

Parameter Name

Common Alarm Switch Valid Level Configuration(25~32)

Description

This parameter specifies the level specifications of special Boolean alarms (numbered 25 to 32). There are two specifications: high level alarm and low level alarm. The bit 0 indicates high level alarm and the bit 1 indicates low level alarm. By default, all the alarms belong to low level alarm.

GUI Value Range

[Alarm Switch 32 (Low Level), Alarm Switch 31 (Low Level), Alarm Switch 30 (Low Level), Alarm Switch 29 (Low Level), Alarm Switch 28 (Low Level), Alarm Switch 27 (Low Level), Alarm Switch 26 (Low Level), Alarm Switch 25 (Low Level)]

Default Value

11111111

Unit

None

Step

-

Modification Rules

None

Configuration Policy

None

Recommended Value

11111111

Parameter Relationship

None

BSC Feature

None

Parameter Class

Parameters About Equipment

Caution

None