Parameter Name |
Semi Site TimeSlot No. |
---|---|
Description |
This parameter specifies the No. of the site timeslot through which the monitoring timeslot over the Abis interface used by the monitoring device gets out of the site. Each timeslot occupies a bandwidth of 64 kbit/s. |
GUI Value Range |
[1,31] |
Default Value |
255 |
Unit |
None |
Step |
- |
Modification Rules |
None |
Configuration Policy |
None |
Recommended Value |
None |
Parameter Relationship |
None |
BSC Feature |
Monitoring timeslot |
Parameter Class |
Parameters About Equipment |
Caution |
This parameter cannot be set to the number of the occupied timeslot. |