Parameter Name |
Float Charging Voltage (V) |
---|---|
Description |
This parameter specifies the float charging voltage for batteries. After this parameter is set, the batteries are charged at the preset float voltage. |
GUI Value Range |
[24.0,28.9] |
Default Value |
26.8 |
Unit |
Volts |
Step |
- |
Modification Rules |
None |
Configuration Policy |
None |
Recommended Value |
26.8 |
Parameter Relationship |
None |
BSC Feature |
None |
Parameter Class |
Parameters About Equipment |
Caution |
This parameter must be higher than DC Undervoltage Alarm Threshold plus 2 and lower than Even Charging Voltage. |