Clock Server Port

Parameter Name

Clock Server Port

Description

This parameter specifies the UDP port number of the IP clock server. If the Abis interface is based on IP transmission, the BTS cannot obtain the clock from the Ethernet lines. To reduce the costs and difficulties in running the BTS, the Abis interface clock is based on IP CLOCK scheme. The IP CLOCK system can be divided into two parts: the server and the client. The server is independent from the BSC6000, and can be also placed inside the BSC6000 cabinet. The clock message packets are sent from the server, transmitted in the network, and received by the client together with the network transmission delay and jitter. After the processes of frequency deviation extracting, filtering, and phase locking, the clock messages are used to synchronize the clock at the client and that at the server end.

GUI Value Range

[0,65535]

Default Value

35001

Unit

None

Step

-

Modification Rules

None

Configuration Policy

None

Recommended Value

35001

Parameter Relationship

None

BSC Feature

None

Parameter Class

Parameters About Transmission

Caution

None


Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.