ShakeHandPeriodA

Parameter Name

ShakeHandPeriodA

Description

This parameter specifies the handshake period between the IP clock on the client and that on the server. Before the IP clock system starts, the handshake between the client and the server is required. The server does not start to send clock information until the handshake succeeds. Handshake period A specifies the period during which the client initiates the handshake with the handshake packet sent from the server.

GUI Value Range

[1,60]

Default Value

5

Unit

Milliseconds

Step

-

Modification Rules

None

Configuration Policy

None

Recommended Value

5

Parameter Relationship

None

BSC Feature

None

Parameter Class

Parameters About Transmission

Caution

None


Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.