Test Timer

Parameter Name

Test Timer

Description

This parameter specifies the interval between two alive messages sent by the BSC. The BSC periodically sends an alive message to the SGSN. If the SGSN responds, the BSC resends the message every time the test timer expires.

For example, value 1 indicates that the timer value is one second, and value 255 indicates that the timer value is 255 seconds.

GUI Value Range

[1,255]

Default Value

30

Unit

Seconds

Step

-

Modification Rules

None

Configuration Policy

If this parameter is set to an excessive value, the BSC cannot receive the response message sent by the SGSN in real time.

If this parameter is set to a modest value, the alive message is sent frequently, thus occupying many bandwidth resources.

Recommended Value

30

Parameter Relationship

None

BSC Feature

None

Parameter Class

Parameters About Equipment

Caution

None